Note: The air valve timer is located next to the tube connector on the air valve body. The timer is capped
with a filter to prevent dirt build-up on the timer. The air valve timing can be adjusted from 5-45 seconds.
Refer to Figure below when adjusting the air valve.
1. Remove the filter cap. Use a screwdriver to tighten or loosen the timer . Turning the timer clock-
wise increases the time, turning the timer counterclockwise decreases the time.
2. Continue to adjust the timer until it is set at the desired length.
3. Replace the filter cap.
Air Valve Tubing Connection
If the air valve is leaking.
1. Depress the release button per the Figure below.
2. Remove and trim the tubing for a fresh surface.
3. Reinsert the tubing until it seats on the tube stop.
Adjusting the Air Valve Metering Time