Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
Installation Instructions TDB3104, WF3204
Bradley Corporation • 215-1470 Rev. H; EN 06-915
112/8/07
Installation Instructions continued . . .
Step 4a: Air Metering Valve assembly for A drain and O drain units without Tie Pipe option
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 7).
2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through the support
tube and connect to valve tube connector. Make sure the spray holes point away from the wall.
3. Place the upper tie bar (notched at both corners of each end) on top of sprayhead parallel to wall.
Connect the longer tie rod to the 4-1/4" tie rod using the coupling nut with hex head set screws.
Run the tie rod assembly down through upper tie bar (see Figure 7 inset) and secure from under-
neath the bowl using lower tie bar (no notches) and hex nut with socket head set screw.
SUPPORT TUBE
GASKET
125-011
SUPPORT TUBE
(STD) S57-005
(TAS) (JUV) S57-006
STD. TIE ROD 176-008A
JUV. TIE ROD 176-008
TIE BAR
PRE-PACK
S45-055
SEMI-CIRC. BOWL
PRE-PACK
S45-1523
1/2" FLEXIBLE
SUPPLY TUBE
TIE BAR
STANDARD PEDESTAL
ASSY. S17-259
TAS PEDESTAL
ASSY. S17-345
TOP COVER
107-099 (A)
107-179 (O)
ACTUATOR MODULE ASSY.
S65-134
RESTRAINING BRACKET
140-126
TIE ROD PRE-PACK
S45-1336
SPRAYHEAD
S05-054B
DRAIN
S45-273
VALVE ASSY.
(
See Fi
g
ure 7a
)
ACCESS PANEL
186-1456
TERREON® SEMI-CIRCULAR BOWL
MODULE COVER
1/8" AIR TUBES
A/O
(A shown)
(PART No. VARIES WITH COLOR OF
BOWL — CONTACT YOUR LOCAL
BRADLEY REP. FOR ASSISTANCE)
COVER
TIE ROD
PRE-PACK
TIE
ROD
COUPLING
NUT
SECTION VIEW OF
A/O UNIT ASSEMBLY
SPRAYHEAD
ACTUATOR
MODULE
ASSY.
TIE
BAR
SUPPLY TUBE
Figure 7