Bradley TDB3108 Specifications Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
TDB3108, WF3208 Installation
20 1/23/2013 Bradley • 215-1471 Rev. F; ECN 13-00-001
Actuator Module Components
* Included in Actuator Assembly (S65-168)
Metering Air Valve Maintenance
Adjust Air Valve Meter Time
Duckbill Check* (198-010)
Piston* (119-227A)
U-Cup* (125-099)
Spring* (135-065)
Screw (160-165)
Actuator Body* (118-279)
Straight Tube Connector* (169-890)
Nut (110-115)
Acutator Bracket (140-743)
Pushbutton Assembly (S08-324)
A
Remove filter cap and use a screwdriver to
tighten or loosen the timer. Turning the timer
clockwise increases the time; turning the
timer counterclockwise decreases the time.
The air valve timer is located next to the tube connector on the air valve body. The timer is capped with
a filter to prevent build-up on the timer. The air valve timing can be adjusted from 5 to 60 seconds.
B
Continue to adjust until the timer is set at
desired length.
C
Replace filter cap over the timer.
Tube Connection Leaks
A
Push in the white manual release button
while pulling the tube out to disconnect the
tube at the connector. No tools are needed.
B
To correct a leak, press tubing firmly into the
connector and make sure it is seated.
C
If leak persists, remove tubing from the fitting
and trim the tubing end square with a razor-
sharp knife. If leak continutes, replace the
fitting or contact your Bradley representative
for assistance.
Air Valve Tubing
Manual Release
Button
Sealing Ring
Tube Stop
Gripping Ridge
Locking Slope
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24

Comments to this Manuals